Informative capsule

About RAID system

More than 10 years of experience in RAID data recovery from all RAID types

OUR PRICES ARE UNBEATABLE!

The best in Quebec, No data No charge

  • Full FREE diagnosis!
  • FREE Pickup !

SPECIALISTS IN RAID SYSTEMS

expérience DANS TOUS LES TYPES DE RAID

KNOW THE PROBLEM

Determine the magnitude of the problem

Important tips

Prices

Our prices are unbeatable!
No data, No charge

Prices

More popular RAID types

01

About RAID

RAID is a data storage virtualization technology that combines multiple physical disk drive components into one or more logical units for the purposes of data redundancy, performance improvement, or both. This was in contrast to the previous concept of highly reliable mainframe disk drives referred to as "single large expensive disk" (SLED). Data is distributed across the drives in one of several ways, referred to as RAID levels, depending on the required level of redundancy and performance.

The different schemes, or data distribution layouts, are named by the word "RAID" followed by a number, for example RAID 0 or RAID 1. Each scheme, or RAID level, provides a different balance among the key goals: reliability, availability, performance, and capacity.

02

RAID 0

It consists of striping, but no mirroring or parity. Compared to a spanned volume, the capacity of a RAID 0 volume is the same; it is the sum of the capacities of the disks in the set. But because striping distributes the contents of each file among all disks in the set, the failure of any disk causes all files, the entire RAID 0 volume, to be lost. A broken spanned volume at least preserves the files on the unfailing disks. The benefit of RAID 0 is that the throughput of read and write operations to any file is multiplied by the number of disks because, unlike spanned volumes, reads and writes are done concurrently, and the cost is complete vulnerability to drive failures.

03

RAID 1

This RAID type consists of data mirroring, without parity or striping. Data is written identically to two drives, thereby producing a "mirrored set" of drives. Thus, any read request can be serviced by any drive in the set. If a request is broadcast to every drive in the set, it can be serviced by the drive that accesses the data first (depending on its seek time and rotational latency), improving performance. Sustained read throughput, if the controller or software is optimized for it, approaches the sum of throughputs of every drive in the set, just as for RAID 0. Actual read throughput of most RAID 1 implementations is slower than the fastest drive. Write throughput is always slower because every drive must be updated, and the slowest drive limits the write performance. The array continues to operate as long as at least one drive is functioning.

04

RAID 5

RAID 5 consists of block-level striping with distributed parity. Unlike RAID 4, parity information is distributed among the drives, requiring all drives but one to be present to operate. Upon failure of a single drive, subsequent reads can be calculated from the distributed parity such that no data is lost. RAID 5 requires at least three disks. Like all single-parity concepts, large RAID 5 implementations are susceptible to system failures because of trends regarding array rebuild time and the chance of drive failure during rebuild (see "Increasing rebuild time and failure probability" section, below). Rebuilding an array requires reading all data from all disks, opening a chance for a second drive failure and the loss of the entire array. In August 2012, Dell posted an advisory against the use of RAID 5 in any configuration on Dell EqualLogic arrays and RAID 50 with "Class 2 7200 RPM drives of 1 TB and higher capacity" for business-critical data.

05

RAID 6

This RAID system consists of block-level striping with double distributed parity. Double parity provides fault tolerance up to two failed drives. This makes larger RAID groups more practical, especially for high-availability systems, as large-capacity drives take longer to restore. RAID 6 requires a minimum of four disks. As with RAID 5, a single drive failure results in reduced performance of the entire array until the failed drive has been replaced. With a RAID 6 array, using drives from multiple sources and manufacturers, it is possible to mitigate most of the problems associated with RAID 5. The larger the drive capacities and the larger the array size, the more important it becomes to choose RAID 6 instead of RAID 5. RAID 10 also minimizes these problems.